11.5 PB
Max storage per ORv2 rack
3
Product lines: SAS-3, SAS-4, NVMe
Up to 70%1
Cost reduction vs. new hardware
0 kg3
Embodied carbon on every remanufactured component
Why RackRenew
Remanufactured OCP Storage. No Compromises.
With an ever-increasing demand for efficient data storage capacity, RackRenew’s remanufactured storage offerings provide a unique balance between affordable, high-density storage and a low carbon footprint.
Available Products
RackRenew 2026 Storage Portfolio
Three product lines covering SAS high-density, next-gen SAS-4, and all-flash NVMe. All OCP ORv2 compliant, all managed via OpenBMC.

Available now · SAS-3 JBOD · High-Density HDD
Bryce Canyon
Hyperscale-designed high-density HDD storage: 72 drives per node in 4 Open Rack units, up to 11.5 PB per rack. Toolless design for rapid serviceability.
| Max capacity / rack | 11.5 PB SAS-3 |
| Nodes per ORv2 rack | 8 nodes |
| Drives per node | 72 × 3.5″ SAS/SATA |
| Drive connectivity | 12 Gb SAS / 6 Gb SATA |
| Front-end NIC | 25 Gb / 50 Gb OCP mezzanine |
| Management | OpenBMC |
| Configurations | Single unit → Full ORv2 rack |
Ideal for: Cold Storage | Data Lakes | Backup & Archive | JBOD / Hadoop
Q4 2026 · SAS-4 JBOD · Next-Gen HDD
Grand Canyon
Architectural upgrade to Bryce Canyon, fully hot-swappable top-service design with SAS-4 drives and dual compute modules per chassis.
| Max capacity / rack | 11.5 PB SAS-4 |
| Nodes per ORv2 rack | 8 nodes |
| Drives per node | 72 × 3.5″ SAS-4 |
| Compute modules | Dual independent per chassis |
| NIC support | OCP 3.0 NIC (SFF) |
| Serviceability | Hot-swap, live operation |
| Management | OpenBMC |
Ideal for: Enterprise SAN/NAS | Disaster Recovery | Media Archives


Q4 2026 · NVMe JBOF · All-Flash
Lightning
First-generation NVMe JBOF delivering PCIe Gen 3 end-to-end connectivity. Purpose-built for AI data pipelines and latency-sensitive workloads.
| Max capacity / rack | 2.7 PB NVMe |
| Nodes per ORv2 rack | 12 nodes |
| Drives per node | 30 × u.2 NVMe |
| Interface | PCIe Gen 3 end-to-end |
| SSD form factors | 2.5″, M.2, 3.5″ NVMe |
| Head nodes supported | Up to 4 per tray |
| Management | OpenBMC (ASPEED AST2400) |
Ideal for: Generative AI | LLM Training | Real-time Inference | AI Data Pipelines
Use Cases
Built for Every Storage Challenge
From petabyte-scale cold storage to sub-100ms AI inference, RackRenew storage solutions are configured for your specific workload requirements.

This first deployment in Italy is a strategic milestone for Qarnot. Made possible through our collaboration with A2A and RackRenew, it gives us the opportunity to address the Italian market’s growing needs for sovereign, energy-efficient cloud computing.
Paul Benoit, CEO and Co-founder, Qarnot
Compute / HPC reference deployment
Brescia’s data center revolution: turning waste heat into urban value
In A2A’s published account, full Phase 2 build out targets 3,500 tonnes of CO₂ avoided annually, recovered heat at 65°C serving about 1,350 apartments, and 16 GWh per year of thermal output. Phase 1, operating today, delivers roughly 800 MWh per year.
1,350
Apartments served with recovered heat (Phase 2 target, A2A)
3,500 t
CO₂ avoided per year (Phase 2 target, A2A)
16 GWh
Thermal output per year (Phase 2 target, A2A)
800 MWh
Thermal output per year, Phase 1 operating today
Explore More
Complete Your Infrastructure Stack
Storage is one piece of the puzzle. Pair it with RackRenew Compute or explore our partner ecosystem for end-to-end solutions.
Certifications
Standards you can audit
Sims Lifecycle Services production facilities: ISO 9001 · ISO 14001 · ISO 27001 · ISO 45001 · RackRenew: OCP Recognized Solution Provider since 2024 · OpenBMC · ORv2 Compliant

ISO certifications held by Sims Lifecycle Services at the production facilities. OCP recognition held by RackRenew.
1 Based on RackRenew like-for-like reference comparisons of remanufactured switch, compute node, and storage node configurations against the market price of equivalent new equipment, held on file by RackRenew. Where a comparison involves a model no longer sold new, RackRenew states that in the comparison.
2 Actual lead times depend on final customer configuration, component availability and destination. RackRenew does not guarantee delivery windows on this website.
3 RackRenew assigns the embodied carbon of a component to its first owner, who incurred the manufacturing emissions at original purchase. A component that enters a second service life through remanufacture is counted at zero embodied carbon for the second owner.

